Osama Abdel Aziz – Testing Commissioning SwitchGear Part 2
$9.00
This course is available
Download link will be sent to you within 3 hours
We appreciate your patience and understanding.
Description
Testing Commissioning SwitchGear Part 2, Osama Abdel Aziz – Testing Commissioning SwitchGear Part 2, Testing Commissioning SwitchGear Part 2 download, Osama Abdel Aziz – Testing Commissioning SwitchGear Part 2 review, Testing Commissioning SwitchGear Part 2 free torent
Osama Abdel Aziz – Testing Commissioning SwitchGear Part 2
Testing Commissioning SwitchGear Part 2
Test All Component OF MV SwitchGear
What you’ll learn
- MCB Test (2 pole & 3 pole) { Pick up current }
- Auxiliary Relays Test ( Pick up & Drop off Timing – Relay Pick up & Drop off Voltage/current – Relay Burden )
- Current Transformer Test (Insulation Resistance Test – CT Characteristics Test – CT Loop Resistance Test -CT Primary Injection Test )
- Voltage Transformer Test (Insulation Resistance Test -VT Ratio & Polarity Test -Winding Resistance Test)
- CB Timing Test ( O – C – OC – CO – OCO )
- Contact Resistance Test For ( CB & Busbar )
- Busbar High Voltage Test
- Maintenance and troubleshooting guidelines for MV SwitchGear
Requirements
The basic electrical principles
Description
Hi my friend !
Looking for a COMPREHENSIVE course about Testing Commissioning MV SwitchGear for Stations ,Switchgears Substations & Distribution Zones ?
If your answer is YES, then you’re definitely in the right place
Why this course is Powerful and Unique ?
The course contents are arranged in a progressive manner to start from beginner level to advanced one
This course gives you a detailed explanation of different power system elements
You will learn through the course all the tests that are done on SwitchGear for example
1- MCB Test (2 pole & 3 pole) { Pick up current }
2- Auxiliary Relays Test ( Pick up & Drop off Timing – Relay Pick up & Drop off Voltage/current – Relay Burden )
3- Current Transformer Test (Insulation Resistance Test – CT Characteristics Test – CT Loop Resistance Test -CT Primary Injection Test )
4- Voltage Transformer Test (Insulation Resistance Test -VT Ratio & Polarity Test -Winding Resistance Test)
5- CB Timing Test ( O – C – OC – CO – OCO )
6- Contact Resistance Test For ( CB & Busbar )
7- Busbar High Voltage Test
8- Maintenance and troubleshooting guidelines for MV SwitchGear
By the end of this course, you will be able to move from identifying all key components of Testing Commissioning SwitchGea to a complete understanding and adjustment of the setting of various protection functions.
I thank you very much for taking the time to check the course content.
I hope See you in the course !
Who this course is for:
- Anyone who wants to learn electric protection and control from scratch
- Electrical Engineering Students
- Electrical Engineering Graduates
- Electrical Engineers who work in the field of substations and switchgears
- Electrical Control Engineers
- Electricians
- Power/Utility Engineer
Course content
Test MCB _ Auxiliary Relays
- Course Overview
- Introduction
- Testing Procedures for Auxiliary Relays and MCB Test
- Test MCB 2 Pole & 3 pole
- Test Auxiliary Relay (RXMVB1)
- Test Timer Relay (RXKL1)
- Interview Question
Test (Current & Voltage ) Transformer
- Testing Procedures For Voltage Transformer
- Test Voltage Transformer By CBC 100
- Test Current Transformer By CT Analyzer
- CT Primary Injection Test
- Primary Injection Test By ODEN AT
- Interview Question
Test Circuit Breaker (CB)
- Contact Resistance Test For (CB & BusBar)
- CB Timing Test By CBA 1000
- Interview Question
High-potential (Hi-Pot) Test
- Why DC Hi-Pot Test is not preferred for testing Ac Switchgear ?
- AC Hi-Pot Test
- Interview Question
Maintenance and troubleshooting guidelines for MV SwitchGear
- Compano 100 Front Panel
- Troubleshooting Guide
- Compano 100 Applications
- Testing ( CT Ratio – CB – protection relay ) By Compano 100
- Interview Question
Instructor
Osama Abdel Aziz
Bachelor of Electrical engineering (power & machines).
Hello,
I’m Osama Abdel Aziz
Electrical Power Systems Engineer
I Have
Bachelor of Degree in Electrical Power and Machines Engineering
i am work naw as protection enginner in EETC company
I share with you my academic and practical experience
I I find a real joy in teaching :).
Choosing an interesting and challenging field such as electrical engineering is a blessing and a gift I’m grateful For
Excellent knowledge and delivering the theory and practical concept with such an ease.
Trainer possesses strong competency in power plant and substation secondary system, scheme like busbar protection, breaker failure protection, substation automation, transformer differential, substation schemes lines/transformer/reactor/busbar, testing & commissioning of relays, scheme testing, testing of GIS/AIS substation equipment, testing of generator protection, on site trainings.
More Information: Please check more value courses here !
Refund is acceptable:
- Firstly, item is not as explained
- Secondly, The Psychotherapy and Spirituality Summit do not work the way it should.
- Thirdly, and most importantly, support extension can not be used.
Thank you for choosing us! We’re so happy that you feel comfortable enough with us to forward your business here.
Reviews
There are no reviews yet.